5 SIMPLE TECHNIQUES FOR ATS SOCOMEC

5 Simple Techniques For ATS Socomec

5 Simple Techniques For ATS Socomec

Blog Article

Safety and dependability ATyS p have the two electrical and mechanical interlocks for maximum security. The 0 position provides electrical protection disconnection and will allow TSE lockout According to IEC60947-3.

Three-section computerized transfer or changeover switching machines displays The provision of electrical ability and quickly transfers the resource by activating a genset.

As well as their integrated electric power and Electrical power measurement functions (having a 2% accuracy degree), programmable inputs/outputs could be utilised to manage load shedding based on a load degree or tariff.

Good Grid, storage for integrating renewable Electrical power and islanding, a established reality Solenbat optimises the Energetic energy effectiveness of buildings Stem, Electricity storage techniques for lessened electrical power billing Paradise, a sensible network for that local community Innovation Near

ATyS g are 3 or 4 pole automated transfer switches, with favourable crack indicator. They incorporate many of the features offered by the ATyS r, and also functions meant for mains/mains and mains/genset purposes.

Protected ATyS p M have the two electrical and mechanical interlocks for the best possible protection. They also element a constructive break indicator, confirming change place with twin mechanical indicators for improved protection.

Secure ATyS p M have each electrical and mechanical interlocks for optimum security. In addition they function a beneficial crack indicator, confirming swap situation with twin mechanical indicators for elevated safety.

Compact ATSE for simple integration in modular DIN enclosure, customized transfer setup and preventive routine maintenance purpose

Handheld remote control interface Specifically made for installations where by the item is enclosed, the distant interface shows product status to the front panel (D10) or displays and controls with access to programming (D20).

and ATS controller. ATyS A switches supply important time conserving in the course of commissioning (approach normally takes 2 to 3 minutes). Owing to the look which allows commissioning as a result of 8 DIP switches, a screwdriver is all of that is required.

Alo alo, năm học mới lại sắp bắt đầu rồi, các bạn học sinh nhỏ của chúng ta đã sẵn sàng đến trường chưa taaaaa.

They can be supposed for use in lower voltage ability supply devices where a short interruption with the load offer is appropriate in the course of transfer.

Probability to set periodic genset startup Chance to set periodic genset startup ATyS p switches offer supplemental capabilities for upkeep. They contain a programmable genset beginning function which will allow the starting off dates and running occasions to be configured.

Adaptable The ATyS C55 is compatible with contactors, breakers and switches. It may also function for all kind of two-resource programs combining mains and gensets.

ATyS p M are one-phase or 3-section modular automatic transfer switches with beneficial break sign. They are really intended for use in very low voltage more info energy offer systems in which a short interruption of the load provide is suitable all through transfer.

Report this page